Sign In | Join Free | My disqueenfrance.com
China Jinan Should Shine Didactic Equipment Co., Ltd. logo
Jinan Should Shine Didactic Equipment Co., Ltd.
Jinan Should Shine Didactic Equipment Co., Ltd. professional vocational educational equipment manufacture!
Active Member

8 Years

Home > Heat Transfer Lab Equipments >

Piping System Convection Heat Transfer Apparatus With Installation Technology Losses

Jinan Should Shine Didactic Equipment Co., Ltd.
Contact Now

Piping System Convection Heat Transfer Apparatus With Installation Technology Losses

Brand Name : ShouldShine

Model Number : SR3005

Certification : ISO9001

Place of Origin : China

MOQ : 1 set

Price : negociate

Payment Terms : L/C, D/A, D/P, Western Union, T/T

Supply Ability : 5000 sets per year

Delivery Time : 35 days

Packaging Details : plastic film+carton+plywood box

Model : SR3005

Application : thermal lab equipment for colleges, university

Dimension : 1.98CBM

Weight : 298kgs

Function : thermal lab equipment educational and training

Brand : ShouldShine

Contact Now

SR3005 Installation technology: losses in a pipe system Thermal Lab Equipment Didactic Equipment

1. Technical data

Brand: ShouldShine


Model:SR3005


Learning Objectives / Experiments


- pressure curve in a closed pipe system with circulation pump


- influence of pipe diameter, flow velocity, change in


cross-section and pipe fittings on the pressure losses


- determination of pump characteristics, system characteristics and the operating point


2. Specification


[1] investigation of the pressure losses at contractions, pipe angles, pipe bends, valves and fittings and pipe elements of different diameter


[2] pipe elements are commercially standard components in heating and sanitary engineering


[3] clear panel mounted on a sturdy, movable frame


[4] closed water circuit with pump and tank


[5] integrated bleed valve on manometer and in the pipe section


[6] flow measurement using rotameter


[7] measurement of the pressure distribution at 13 pressure measuring points, display with 13 tube

manometers


3. Technical Data


Pump - 3 stages - max. flow rate: 4,5m³/h - max. head: 6m


Tank: approx. 5L


Measuring range - flow rate: 100...1000L/h - pressure: 1600mmWC


Dimensions and Weight LxWxH: 1900x700x2020mm Weight: approx. 340kg


Required for Operation


230V, 50Hz, 1 phase

Arrange delivery within 45 days upon receipt of payment.

Please see below photo for detailed package.

Piping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology Losses


Training Room Photo
Piping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology Losses


Company Information

We supply professional educational training equipment and technical teaching equipment, which has been widely applied in Engineering Universities, Polytechnics, Technical Institute, Vocational Schools as well as Industry workforce Development Programs and Training Center. Our products allow students to learn and experiment through valuable hands-on experience, and the technology covered by our training equipment provides knowledge, experiments and didactic skills development that are of critical importance to today´s and tomorrow´s careers.

Piping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology LossesPiping System Convection Heat Transfer Apparatus With Installation Technology Losses
Photo for Clients Visiting Factory
Piping System Convection Heat Transfer Apparatus With Installation Technology Losses

Piping System Convection Heat Transfer Apparatus With Installation Technology Losses

Piping System Convection Heat Transfer Apparatus With Installation Technology Losses

Piping System Convection Heat Transfer Apparatus With Installation Technology Losses
Service

We supply supply7*24 hours service, customer design service, OEM service, buyer label service. With professional engineers team and sales team, we assure you good product quality.

Certificate
Our products takes ISO9001 product management system.

No. Feature Name Details
1 Customer design Yes
2 Warranty 1 year, 2 years, 3 years or 5 years according to client requirements
3 Package Plastic film+ carton+ Fine plywood
4 Products standard International didactic equipment standard
5 Application range Educational equipment for university, college, vocational training centers
6 Company philosophy Supply best quality Chinese products to the worldwide schools.
7 Self owned brand Shouldshine, SSEDU, JSS.
8 Production time From 10 days to 60 days according to different items

Product Tags:

heat transfer laboratory equipment

      

heat transfer apparatus

      
China Piping System Convection Heat Transfer Apparatus With Installation Technology Losses wholesale

Piping System Convection Heat Transfer Apparatus With Installation Technology Losses Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Jinan Should Shine Didactic Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0